| Variations : Calc. 7 |
| Fan extraction |
|
| Outside temperature (in Centigrade) |
|
| Desired room temperature (in Centigrade) |
|
| |
|
Ceilings without Insulation for Top Floors and Single Storey Buildings : Calc. 8
The Heatloss Calculator assumes that ceilings on top floors and single storey buildings are insulated. If not insulated please tick "no" |
| Ceiling insulation |
|
| |
|
Floors with insulation: Calc. 9
The Heatloss Calculator assumes that floors in Basement/Ground Floor rooms and Single Storey buildings are not insulated, if they are insulated please tick "yes" |
| Floor insulations |
|
|
 |
Heatloss Calculator assumes following data
> Steady state heatloss principle
> Installation complies to BS5449
> Temperature variations
External walls, floors and ceilings : 22C
Internal floors : nil
Internal ceilings : 5C
Internal walls : nil (15C when unheated other side)
Party walls : nil (15C when unheated other side)
Windows/skylights : 22C
> Air Changes 2 per hour
> U values
Air charge rate : 0.66
Insulated external floor : 0.4
Uninsulated external floor : 0.8
Insulated external ceiling : 0.4
Uninsulated external ceiling : 2.0
Internal ceiling : 1.7
Party wall : 1.7
External wall: solid :2.1, cavity:1.5, insulated:0.5
Single glass window : 5.0
Double glass window : 2.5
Sigle glass skylight : 6.8
Double glass skylight : 4.0 |
|
NOTES
(i) If in doubt about Wall Type use 'solid'
(ii) Measure entrie lenght of outside wall(s) including windows and any outside doors

(iii) Include any glass doors |
|